Ethernet Transmission
Video/Audio/Data Transmission
SFP Transceivers
Accessories► Integrated 90-240VAC power input, no need extra power adapter
► 4-Port 10/100/1000T 802.3bt PoE 90W + 2-Port 100/1000X SFP
► Supports IEEE802.3af/at PoE+(30W) or IEEE802.3bt PoE++ (90W), Max. PoE Output Power: 100W
The UF-AIS6204GP90 Series is an AC-powered unmanaged industrial Gigabit PoE++ switch designed for industrial Ethernet networks, IP surveillance, intelligent transportation systems, and remote network installations.
It features four 10/100/1000BASE-T RJ45 ports supporting IEEE 802.3af/at/bt PoE, together with two 100/1000BASE-X SFP fiber optic interfaces for flexible fiber uplink connections.
Unlike conventional industrial PoE switches that require an external DC power supply, the UF-AIS6204GP90 integrates a wide-range 90–240VAC power input, eliminating the need for a separate AC-to-DC power adapter. Each PoE port supports up to 90W output, while the total PoE power budget is up to 100W.
Designed for demanding industrial environments, the switch features a fanless aluminum housing, IP40 protection, DIN-rail or wall mounting, and a wide operating temperature range of -40°C to +80°C.
Two AC input connection options are available: terminal block and C5 socket.
1. What is the power input of the UF-AIS6204GP90 Series?
It features an integrated 90–240VAC power input, eliminating the need for a separate external AC-to-DC power adapter.
2. How many PoE ports does this industrial switch provide?
It provides four Gigabit RJ45 PoE ports supporting IEEE 802.3af/at/bt standards.
3. Does each PoE port support 90W output?
Yes. Each PoE port supports up to 90W. However, the total PoE power budget for the entire switch is up to 100W, so the available power must be shared among connected devices.
4. How many fiber ports does the switch have?
It provides two 100/1000BASE-X SFP slots. Compatible 100M or Gigabit SFP transceivers can be selected according to the fiber type and transmission distance.
5. Does the switch require an external power adapter?
No. The switch has an integrated 90–240VAC power supply. It can be connected directly to a suitable AC power source using the selected AC input connection.
6. What are the differences between the TB and C5 versions?
The UF-AIS6204GP90-TB uses a terminal block AC connection, while the UF-AIS6204GP90-C5 uses a C5 socket AC connection.
7. Can the switch operate in high-temperature environments?
Yes. Its specified operating temperature range is -40°C to +80°C.
8. Is the switch managed or unmanaged?
The UF-AIS6204GP90 Series is an unmanaged industrial Ethernet PoE++ switch designed for straightforward plug-and-play network deployment.
Looking for an AC-powered industrial PoE++ switch with high-power PoE ports and dual fiber uplinks?
Contact UTP Fiber with your PoE device requirements, fiber type, transmission distance, and preferred AC connection to discuss the UF-AIS6204GP90 series for your project.
AC Powered Industrial 4-Port 90W PoE++ Switch with 2 SFP Fiber Uplinks
Product Overview
Frequently Asked Questions
Request a Quote
Integrated AC Power Supply: Supports 90–240VAC input without requiring an external power adapter.
4-Port Gigabit PoE++: Four 10/100/1000BASE-T RJ45 ports support IEEE 802.3af/at/bt PoE, with up to 90W per port.
2 SFP Fiber Uplinks: Two 100/1000BASE-X SFP slots support flexible fiber connections using compatible SFP transceivers.
Up to 100W Total PoE Budget: Provides a total PoE power budget of up to 100W across the four PoE ports.
Flexible AC Connection: Available with terminal block or C5 socket AC input.
Industrial Temperature Range: Designed for operation from -40°C to +80°C.
Fanless Aluminum Housing: Passive cooling design with no cooling fan, reducing maintenance requirements.
Industrial Mounting: Supports DIN-rail and wall mounting.
Gigabit Switching Performance: 12Gbps switching capacity, store-and-forward processing, and 9KB jumbo frame support.
Network Protection: Ethernet ESD protection up to ±8kV contact and ±15kV air discharge, with ±4kV surge immunity as specified.
Connect IP cameras and other Ethernet surveillance devices through PoE ports, with fiber uplinks connecting remote monitoring networks.
Provide Gigabit Ethernet connectivity and PoE power for compatible transportation monitoring and roadside network equipment.
Connect Ethernet-enabled industrial devices in manufacturing facilities, control cabinets, and distributed industrial installations.
Use the two SFP interfaces to establish fiber uplinks between network segments, helping extend connectivity beyond conventional copper Ethernet distances.
Supply PoE power to compatible high-power network devices such as PTZ cameras, wireless access points, and other IEEE 802.3bt powered devices, subject to the total 100W power budget.
|
Ethernet |
|
|
Standards: |
IEEE 802.3 Ethernet |
|
IEEE 802.3u Fast Ethernet |
|
|
IEEE 802.3ab Gigabit Ethernet |
|
|
IEEE 802.3z Gigabit Ethernet over Fiber Optic |
|
|
IEEE 802.3az Energy Efficient Ethernet (EEE) |
|
|
IEEE 802.3bt Power over Ethernet Plus Plus |
|
|
IEEE 802.3at Power over Ethernet Plus |
|
|
IEEE 802.3af Power over Ethernet |
|
|
Forward & Filtering Rate: |
14,880pps (10Mbps) |
|
148,800pps (100Mbps) |
|
|
1,488,000pps (1000Mbps) |
|
|
Packet Buffer Size: |
1M |
|
Switch Fabric: |
12Gbps |
|
Processing Type: |
Store-and-Forward |
|
Max Packet Length: |
9K Bytes Jumbo Frame |
|
Address Table Size: |
2K MAC Addresses |
|
Interface |
|
|
Copper Ports: |
4 x 10/100/1000BASE-T RJ45 auto-MDI/MDI-X ports |
|
PoE Injector Ports |
4 ports with 802.3bt 90W PoE++ injector function (Ports 1 to 4) |
|
SFP Ports: |
2 x 100/1000BASE-X SFP interfaces (auto detection) |
|
Power over Ethernet |
|
|
PoE Standard |
IEEE 802.3bt Power over Ethernet Plus Plus type 4 PSE Backward compliant with 802.3at Power over Ethernet Plus PSE |
|
PoE Power Supply Type |
802.3bt, UPoE End-span/Mid-span |
|
Power Pin Assignment |
1/2(+), 3/6(-), 4/5(+), 7/8(-) |
|
PoE Power Output |
IEEE 802.3af Standard
IEEE 802.3bt Standard |
|
Power budget |
Max. PoE output power budget 90W for each PoE port |
|
Lightning protection |
The Industrial Switch provides contact discharge of ±8KV DC and air discharge of ±15KV DC for Ethernet ESD protection. It also supports ±4KV surge immunity to improve product stability and protects users’ networks from devastating ESD attacks, making sure the flow of operation does not fluctuate. |
|
Environmental |
|
|
Operating Temperature: |
-40°C to 80°C (-40°F to 176°F) |
|
Storage Temperature: |
-40°C to 85°C (-40°F to 185°F) |
|
Relative Humidity: |
5% to 95% non-condensing |
|
MTBF: |
907,476 hours @ Telcordia SR-332 Standard |
|
Heat Dissipation: |
10 BTU/h (Non-PoE) 420 BTU/h (30W PoE) |
|
Cooling: |
Passive Cooling, Fanless Design |
|
Noise Level: |
0 dBA |
|
Electrical and Mechanical |
|
|
Input Power: |
90-240VAC |
|
Connector: |
C13 Socket or Terminal Block Optional |
|
Power Consumption: |
105W Max. (PoE in use) |
|
5W Max. (PoE not in use) |
|
|
LED Indicators: |
|
|
PWR: |
Power Status |
|
RJ45: |
Link/Act: connect-always; data exchange-twinkle |
|
Fiber: |
Link/Act: connect-always; data exchange-twinkle |
|
PoE: |
PoE Status |
|
Dimensions (LxWxH): |
100 x 82 x 49.5 mm |
|
Weight: |
406g |
|
Casing: |
Aluminum Case |
|
Mounting Options: |
DIN-Rail / Wall-mount |
|
Regulatory Approvals |
|
|
EMC/EMI/EMS |
FCC Part15 Class A CE-EMC/LVD RoHS EN61000-4-2 (ESD): LEVEL 4 IEC 6100-4-2 (EFT): LEVEL 4 IEC 6100-4-2 (Surge): LEVEL 4 IEC 6100-4-2 (CS):LEVEL 3 IEC 61000-4-2(PFMP) : LEVEL 5 EN61000-4-3 (RS): LEVEL 4 |
|
Shock |
IEC60068-2-27 |
|
Freefall |
IEC60068-2-31 |
|
Vibration |
IEC60068-2-6 |
|
Safety |
EN 60950-1, UL 60950-1, CSA C22.2 No.60950-1, UL 508 |
|
Model |
Description |
|
UF-AIS6204GP90-TB |
AC Powered Industrial 4-Port 10/100/1000T 802.3bt PoE 90W + 2-Port 100/1000X SFP Gigabit Ethernet Switch, Max. PoE Power Budget: 100W, 90-240VAC power input - Terminal Block |
|
UF-AIS6204GP90-C5 |
AC Powered Industrial 4-Port 10/100/1000T 802.3bt PoE 90W + 2-Port 100/1000X SFP Gigabit Ethernet Switch, Max. PoE Power Budget: 100W, 90-240VAC power input - C5 Socket |
|
SFP Options |
► SFP option. Please select your SFP on our SFP Options Page (Industrial SFP). |
|
► SFP module is to be purchased separately. |
|
|
Mounting Options |
► Default DIN-Rail Bracket installed; Wall Mount Bracket is included. |
|
Power Cable Options |
► Power Cable not included |
|